Air, vacuum and hydrostatic tank testing to EN 13160. Remediation of damaged above-ground and underground tanks using the plastic lining method — service life extended by 17+ years. Technical inspection certificate, since 2009.
Tank leak testing is a legal requirement for all above-ground and underground fuel tanks in North Macedonia. The Inspectorate requires proof of tightness before commissioning, during technical inspections and after remediation work. Our team carries out all the standard tests — air pressure, vacuum and hydrostatic — in line with EN 13160 and the regulations of North Macedonia.
With 17+ years of experience we work with all types of tanks: ASTs and USTs for petrol stations, industrial tanks, heavy fuel oil tanks and heating tanks. We issue certificates accepted for technical inspection, by the Water Protection Inspectorate and for internal ISO procedures.
For tanks where the test shows damage, we offer remediation using the plastic lining method — we fit an internal plastic lining that extends the tank's life by 17+ years, without the need for costly replacement. The process complies with EN regulations and is certified for fuel, water and industrial liquid tanks.
Every leak testing method and remediation of damaged tanks — with complete documentation.
The standard test for underground tanks. Fast, non-invasive, with precise leak-rate measurement.
High sensitivity for detecting microscopic cracks. The standard for new installations and after remediation.
The most reliable test for large tanks and critical installations. Leak details are visible immediately.
An internal plastic lining extends service life by 17+ years. An alternative to costly tank replacement.
Documentation accepted for technical inspection, by the Water Protection Inspectorate and for internal ISO procedures.
All tests and methods follow the European standard EN 13160 — accepted beyond North Macedonia's borders too.
From the first call to the final documentation — a transparent, documented and compliant process.
Notification 48h before the appointment.
ADR vehicle for disposing of the contents.
Emptying + mechanical cleaning.
Leak test, flow check.
Report, photos, proof of disposal.
Mandatory 2x a year.
Every 3-6 months.
Depending on throughput.
Large garages, shopping centres.
Airport hangars and aprons.
17 years of experience, over 500 industrial sites, a 100% eco-friendly approach.
Monthly and annual contracts.
Automatic reminders.
For the water inspectorate.
Transparent, no hidden costs.
Extends the interval.
Free on-site assessment within 24h. Project-based quote.